How To Wire A, Way Switch With 2 Lights - Hi all, new to smartthings, however no longer new to electric work. Query is that this…if i've a 3-way circuit with (currently dumb) switches, when i make the circuit “clever” do i need to update each switches with a smartthings compatible switch or just considered one of them? Thanks earlier.

The approach shown on your diagram will certainly work with networked master switches wherein the auxiliary switches are dummies linked with physical traveller wires. That’s essentially the same setup that the ge three-way set makes use of.

Edit: earlier than all and sundry tells me off for having a secondary switch and not using a earth; the switch wires on a fibaro dimmer 2 perform at low voltage (about 3v). As long as there are not any other 240v circuits in secondary location you won’t have a trouble. If you’re now not certain approximately this or any of the above don’t strive it.

Hello all, new to smartthings, but not new to electrical paintings. Question is this…if i've a three-manner circuit with (currently dumb) switches, after i make the circuit “smart” do i have to update both switches with a smartthings compatible transfer or just one among them? Thanks in advance.

Multiple more questions. Lets anticipate that i want to use ge/jasco switches in this case. I get that a 3-way circuit wishes a clever transfer and an add-on switch. What about a 4-way circuit (aka three or extra switches controlling one mild). It's far usual in the us that a three-way is stressed in a kind of figure 8 sample wherein flipping one toggle transfer closes its loop and cuts out the opposite transfer. Which could’t be executed with community switches due to the fact the radio within the transfer needs to continually have strength in order that it is able to listen the subsequent “on” command. The only exception to that is if you most effective have a three-way set up (two switches, one light fixture) and you are using an inside the wall micro at the fixture, and that micro is able deal with input switches. Lots of them are. In this example, there could be physical vacationer wires going from the dumb wall switch to the micro on the light.